详细信息
Compressive bearing capacity field test of a vertical-inclined combined core high-pressure jet grouting pile group foundation ( SCI-EXPANDED收录)
文献类型:期刊文献
英文题名:Compressive bearing capacity field test of a vertical-inclined combined core high-pressure jet grouting pile group foundation
作者:Li, Meilin Zheng, Gang Lou, Qiang Zhao, Yu Zhou, Haizuo Jiao, Weiguo Wang, Hong Gan, Fei
第一作者:Li, Meilin
通信作者:Gan, F[1]
机构:[1]Guizhou Univ, Sch Civil Engn, Guiyang 550025, Peoples R China;[2]Tianjin Univ, Sch Civil Engn, Tianjin 300072, Peoples R China;[3]Guizhou Power Transmiss & Transformat Co LTD, Guiyang 550000, Peoples R China;[4]Guizhou Inst Technol, Sch Civil Engn, Guiyang 550001, Peoples R China
第一机构:Guizhou Univ, Sch Civil Engn, Guiyang 550025, Peoples R China
通信机构:corresponding author), Guizhou Univ, Sch Civil Engn, Guiyang 550025, Peoples R China.
年份:2026
卷号:65
外文期刊名:TRANSPORTATION GEOTECHNICS
收录:;Scopus(收录号:2-s2.0-105048921546);WOS:【SCI-EXPANDED(收录号:WOS:001867118600001)】;
基金:This work was supported by the National Natural Science Foundation of China (Grant No. 52568047, 52508373 and 42567026) .
语种:英文
外文关键词:Vertical-inclined combined core high-pressure; jet grouting pile group foundation; Compressive bearing capacity; Internal force; Skin friction; Soil-to-pile load ratio; Failure mode
摘要:Traditional transmission tower foundations in mountainous infrastructure corridors face challenges such as limited mechanized construction, difficult material transport, and insufficient stability under complex loading. This study presents a prototype-scale field compression test on a vertical-inclined combined core high-pressure jet grouting pile foundation (VICP foundation). The study examined the load-settlement response, axial force, bending moment, lateral friction, soil-pile load ratio, and macroscopic failure modes. The VICP pile group reached an ultimate compressive capacity of 4200 kN, which is 3.23 times the capacity of the single vertical pile (1300 kN). The corresponding pile-group efficiency relative to five independent single piles is approximately 0.65. The measured mean compressive strength of the jet-grouted pile-core material was 18.23 MPa, and the direct-shear strength parameters were c = 1.26 MPa and phi = 51.02 degrees. Axial forces were largest near the pile head and decreased with depth. The inclined piles carried a larger axial component than the vertical pile below 3600 kN and exhibited reverse bending between 1.0 and 2.5 m from the pile top. The skin friction of the inclined piles decreased downward, whereas that of the vertical pile increased with depth. The soil-to-pile load ratio first decreased from 0.32 to approximately 0 and then increased to 0.41; at the final loading stage, the soil and piles carried 29% and 71% of the total vertical load, respectively. These results indicate that the enhanced bearing performance of the VICP foundation results from the combined action of pile-group interaction, cap-soil contact, and the axial-load component mobilized by the inclined piles. The findings provide prototype-scale evidence for the design of special pile foundations for transmission towers and other mountainous transportation and infrastructure projects.
参考文献:
正在载入数据...